-40%

Euchner CES-AR-AES-12, CESARAES12 Safety Unit DIN Rail 4x Safety Relays

$ 105.59

Availability: 100 in stock
  • MPN: Does Not Apply
  • Condition: Excellent used condition, pulled from working environment.
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: Germany
  • Brand: EUCHNER
  • Type: Safety Relay
  • Item must be returned within: 30 Days
  • Mounting Style: DIN Rail
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted

    Description

    Euchner CES-AR-AES-12, CESARAES12  Safety Unit DIN Rail 4x Safety Relays
    Excellent used condition, pulled from working environment.
    This item is free shipping to the lower 48 States, contact us for a quote elsewhere.
    Feel Free to contact us with any questions
    Thank you for your interest and have a great day!
    Manufacturers page: euchner-usa.com/en-us/a/098225/
    Important:
    A switch chain comprising the following safety switches can be connected to the AR evaluation unit:
    CES-AR-C01 / CES-AR-C02 / CES AR-C04 / ESL-AR / CET- AR / CTP-AR
    Function
    The AR evaluation unit is used to evaluate the individual safety switches in a CES-AR-... switch chain and the safe interruption of a safety circuit.
    The unit has two inputs for connection of a CES-AR... switch chain. The safety contacts are switched as a function of the input signals. Downstream parts of the safety circuit can be monitored using a feedback loop.
    The switching states of the connected safety switches can be signaled by means of monitoring outputs.
    If the actuator on one of the safety switches in the switch chain is moved out of the actuating range, the AR evaluation unit opens its contacts and the corresponding monitoring output is reset.
    The system is designed so that failures will not result in the loss of the safety function. The occurrence of failures is detected by cyclic self-monitoring at the latest at the next demand to close the safety contacts.
    The system can be started either manually using a start button or automatically.
    Category according to EN ISO 13849-1
    Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:
    Category 4/PL e according to EN ISO 13849-1
    Each safety path is independently safe.
    LED indicator
    STATE
    Status LED
    DIA
    Diagnostic LED
    OUT
    Safe state/self-test
    Important:
    The plug-in connection terminals are not included and must be ordered separately.
    AR evaluation unit CES-AR-AES-12
    Central evaluation of an AR switch chain
    Status of each individual switch can be seen
    For switch chains of up to 12 devices
    Four individual safe relay contacts
    Category 4/PLe according to EN ISO 13849-1
    Mechanical values and environment
    Shock and vibration resistance
    In acc. with EN 60947-5-3
    Dimensions
    114 x 99 x 45
    Housing material
    Housing
    Plastic PA6.6
    Weight
    Net
    0,25 kg
    Ambient temperature
    At U
    B
    = DC 24 V
    -20 ... 55 °C
    Atmospheric humidity
    Not condensing
    max.80 % rH
    Degree of protection
    IP20
    Mounting method
    Mounting rail 35 mm according to EN 60715
    Ready delay
    max.8 s
    Connection
    Plug-in screw terminals coded
    Number of LED displays
    3
    O1 ... O12
    Number of monitoring outputs
    12
    13/14, 23/24, 33/34, 43/44
    Number of safety contacts
    4 Relays with internally monitored contacts
    Mechanical life
    Relay
    10 x 10
    6
    Switching frequency
    1 Hz
    Electrical connection ratings
    Operating voltage DC
    U
    B
    24 V DC
    -10% ... 10% Regulated, residual ripple < 5 %
    Current consumption
    IB (with relay energized)
    1200 mA
    Fusing
    External (operating voltage UB)
    2,5 ... 8 A
    Rated insulation voltage U
    i
    250 V
    Rated impulse withstand voltage U
    imp
    4 kV
    EMC protection requirements
    In acc. with EN 60947-5-3
    Degree of contamination (external, according to EN 60947-1)
    2
    Connection cross-section
    0,14 ... 2,5 mm²
    Switching delay from state change
    max.480 ms
    STATE
    LED indicator
    STATE
    Green LED: Status of the device
    OUT
    LED indicator
    OUT
    Yellow LED: State of the AR chain
    DIA
    LED indicator
    DIA
    Red LED: Fault display
    Type of output
    Semiconductor output, p-switching, short circuit-proof
    Output voltage
    LOW
    0 ... 1 V DC
    HIGH
    UB - 20% ... UB V DC
    Output current
    max.20 mA
    O1 ... O12
    Type of output
    Semiconductor outputs, p-switching, short circuit-proof
    Output voltage
    High
    UB - 20% ... UB V DC
    LOW
    0 ... 1 V DC
    Output current
    max.20 mA
    OUT AR
    Type of output
    Semiconductor output, p-switching, short circuit-proof
    Output voltage
    LOW
    0 ... 1 V DC
    HIGH
    UB - 20 % ... UB V DC
    Output current
    max.20 mA
    Start button S
    Response delay
    Start button
    300 ... 600 ms
    Actuating duration
    Start button
    min.250 ms
    Input current
    HIGH
    5 ... 8 ... 10 mA
    Input voltage
    LOW
    0 ... 2 V DC
    HIGH
    15 ... UB V DC
    Y1/Y2
    Current via feedback loop
    5 ... 8 ... 10 mA
    permissible resistance in feedback loop
    max.600 Ω
    IA, IB
    Number of connectible safety switches
    max.12
    Safety inputs
    2 (for CES-AR switch chain)
    13/14, 23/24, 33/34, 43/44
    Switching current
    Relay outputs (at switching voltage AC/DC 21 ... 60 V
    1 ... 300 mA
    Relay outputs (at switching voltage AC/DC 5 ... 30 V)
    10 ... 6000 mA
    Relay outputs (at switching voltage AC 5 ... 230 V)
    10 ... 5000 mA
    Fusing
    External (safety circuit) according to EN 60269-1
    6 AgG or 6 A circuit breaker (characteristic B or C)
    Utilization category acc. to EN 60947-5-1
    AC-15
    230 V 5 A
    DC-13
    24 V 5 A
    AC-12
    60 V 0.3 A
    30 V 6 A
    DC-12
    60 V 0.3 A
    30 V 6 A
    Discrepancy time
    Between the operating points of both relays
    max.25 ms
    Reliability values according to EN ISO 13849-1
    Monitoring of the safety guard position
    Category
    4
    Performance Level
    PL e
    PFH
    D
    1.5 x 10
    -8
    Number of switching cycles
    ≤ 0.1 A at 24 V DC
    max.720000 1/Jahr
    ≤ 1 A at 24 V DC
    max.540000 1/Jahr
    ≤ 3 A at 24 V DC
    max.107000 1/Jahr
    Mission time
    20 y